        Compensation conductor

        補(bu)償導(dao)線.jpg
        • 補償導線(xian).jpg
        Compensation conductor should be divided into extension type and compensation type two kinds, fluori…

        Description:

        An overview, cables:
        Compensation wires and compensation cables, to a certain temperature range (including temperature) with the matched the thermocouple thermoelectric emfs values the same couple or more with insulated wire or cable, use them to connect the thermocouple and measuring devices, to compensate them with the error produced by the temperature change of the thermocouple junction, compensation wires and compensation cables are divided into extension type and compensation type two kinds, fluorine plastic wire or cable and silicon rubber insulation resistance to high temperature compensation is more high temperature resistant, cold resistant, resistant to acid and alkali oil and water, don't delay burning, anti-aging and other advantages, the products are widely used in petroleum, chemical industry, electric power, metallurgy, medicine, textile and other factories and scientific research departments in the temperature measurement and control system.
        Second, the compensating conductor standards:
        GB/T4989-94 (equivalent to the IEC584-3 standard)
        Three, compensation conductor used features:
        1, the highest working temperature conductor: 70 ℃ polyvinyl chloride (PVC) 200 ℃ and 180 ℃ 105 ℃ silicone rubber fluorine plastic meltability polytetrafluoroethylene (PTFE) 260 ℃
        2, the lowest temperature:
        PVC sheathed: fixed installation to 40 ℃, the fixed installation to 15 ℃.Fluorine plastic and silicone rubber sheath: fixed installation - 60 ℃, the fixed installation - 20 ℃.
        3, cable allows bending radius: the minimum armored cable is 6 times of overall diameter;Copper tape screened or steel tape armoured cable minimum 12 times of cable diameter;Fluorine plastic insulation and sheath minimum 10 times of cable diameter.
        Four, compensation conductor should be the basic model and name:

        model

        Products name said

        KX-GS-VV

        PVC insulated PVC sheathed general in dividing precision grade K thermocouple compensating cable

        KX-GS-VVP

        PVC insulated PVC sheathed wire braided total screen precision grade K is commonly used in dividing thermocouple compensating cable

        KX-GS-VPV

        PVC insulated PVC sheathed wire woven on screen in general by the level of precision indexing number K thermocouple with compensation cables

        KX-GS-VPVP

        PVC insulated PVC sheathed wire woven on total screen is usually in dividing precision grade K thermocouple with compensation cables

        KX-HS-FF

        Fluorine plastic insulation and sheath heat by the level of precision index number K thermocouple with compensation cables

        KX-HS-FFP

        Fluorine plastic insulated and sheathed wire braided total screen heat by the level of precision indexing number K thermocouple with compensation cables

        KX-HS-FPF

        Fluorine plastic insulated and sheathed wire weaving on screen heat by the level of precision indexing number K thermocouple compensating cable

        KX-HS-FPFP

        Fluorine plastic insulated and sheathed wire weaving on total screen heat in dividing precision grade K thermocouple compensating cable

        KX-HS-FG

        Fluorine plastic insulation silicone rubber sheath heat by the level of precision index number K thermocouple with compensation cables

        KX-HS-FGP

        Fluorine plastic insulation silicone rubber sheath copper wire braided total screen heat in dividing precision grade K thermocouple compensating cable

        KX-HS-FPG

        Fluorine plastic insulation silicone rubber sheath copper wire woven on screen heat by the level of precision indexing number K thermocouple compensating cable

        KX-HS-FPGP

        Fluorine plastic insulation silicone rubber sheath copper wire woven on total screen heat in dividing precision grade K thermocouple compensating cable

        KX-HS-FV

        Fluorine plastic insulated PVC sheathed heat by the level of precision index number K thermocouple with compensation cables

        KX-HS-FVP

        Fluorine plastic insulated PVC sheathed wire braided total screen heat by the level of precision indexing number K thermocouple with compensation cables

        KX-HS-FPV

        Fluorine plastic insulated PVC sheathed wire woven on screen heat by the level of precision indexing number K thermocouple compensating cable

        KX-HS-FPVP

        Fluorine plastic insulated PVC sheathed wire woven on total screen heat in dividing precision grade K thermocouple compensating cable

        KX-HS-GG

        Silicone rubber insulated and sheathed heat by the level of precision index number K thermocouple with compensation cables

        KX-HS-GGP

        Silicone rubber insulated and sheathed wire weaving total screen heat in dividing precision grade K thermocouple compensating cable

        KX-HS-GPG

        Silicone rubber insulated and sheathed wire weaving on screen heat by the level of precision indexing number K thermocouple compensating cable

        KX-HS-GPGP

        Silicone rubber insulated and sheathed wire weaving on total screen heat in dividing precision grade K thermocouple compensating cable

        Note: 1, the above models only list the KX, other such as SC, KC, EX, BC, TX, JX need to change the first model;
        2, before this Ann model compensating cable type charging "ia";
        3, flame retardant, compensation cable type filling before "out";If you need armoured can refill "22" after the model;If you want to block, can indicate shielding in style: P, P1 tin plated copper wire, copper wire P2 copper strip, P3 lu: su composite film;Conductor for multiple strands of soft core, should inject "R" after the model.
        4, PTFE ZR190 for imported materials, heat-resistant 260 ℃.
        Five, compensation conductor should be the main technical indicators:

        Compensation conductor model

        With thermocouple

        Thermocouple index number

        Compensating lead wire

        Insulating layer coloring

        The anode

        The cathode

        The anode

        The cathode

        SC

        10 - platinum platinum rhodium thermocouple

        S

        SPC (copper)

        SNC (copper, nickel)

        red

        green

        RC

        13 - platinum rhodium platinum thermocouple

        R

        RPC (copper)

        The RNC (copper, nickel)

        red

        green

        KCA

        Nickel chrome - nickel silicon thermocouple

        K

        KPCA (iron)

        KNCA (copper, nickel)

        red

        blue

        KCB

        Kleiner perkins caufield & byers (copper)

        KNCB (copper, nickel)

        red

        blue

        KX

        KPX (nickel chrome)

        KNX (nickel silicon)

        red

        black

        NC

        Nickel chromium silicon - nickel silicon thermocouple

        N

        NPC (iron)

        NNC (copper, nickel)

        red

        grey

        NX

        NPX (nickel chromium silicon)

        NNX (nickel silicon)

        red

        grey

        EX

        Copper nickel chrome - nickel thermocouple

        E

        EPX (nickel chrome)

        ENX (copper, nickel)

        red

        brown

        JX

        Iron, copper and nickel thermocouple

        J

        JPX (iron)

        JNX (copper, nickel)

        red

        The purple

        TX

        Copper, copper nickel thermocouple

        T

        TPX (copper)

        TNX (copper, nickel)

        red

        white

        Note: type the first letter and the thermocouple corresponding to the index, the second letter in "C" said compensation conductor, the letter "X" said compensation conductor should be extended type.SC type can be compensation conductor with R type degree thermocouple.