1. <dir id="mSLL8A"><q id="mSLL8A"></q></dir>

        Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

        Damping type metal tube rotameter

        18金屬筦(guan)轉(zhuan)子(zi)流(liu)量(liang)計(ji)(阻(zu)尼(ni)式).png
        • 18金屬筦(guan)轉(zhuan)子(zi)流量(liang)計(阻(zu)尼式(shi)).png
        ZW-LZ series Damping type metal tube rotameter Is a variable area flow meter based on float position…

        Description:

        Productoverview:

        ZW-LZ series Damping type metal tube rotameter Is a variable area flow meter based on float position measurement.The concept of full metal structure, Modular design, because of its small volume, small pressure loss, large measuring range ratio (10:1), easy installation and maintenance, it is widely used in various industries complex, harsh environment, small volume and low velocity, a variety of harsh medium conditions of traffic measurement and process control.According to the needs of different users and different occasions, there are a variety of measurement for user selectable; according to the output form of a local indication, remote control alarm output type, type, form a local indication according to the output, output type, remote control alarm type; according to the classification shown proof, and can be divided into ordinary type, intrinsic safety type, explosion proof type three isolation.

        Second, working principle:

        ZW-LZ series damping type metal tube rotameter is the medium to be measured through a conical measuring tube float from upper and lower ends of the differential pressure generated form the upward force, when the float was immersed in a fluid on the lift is greater than the weight of the float, the float will rise, annulus area increases, the annulus fluid velocity decreased immediately float the lower end of the differential pressure is reduced, to float upward force also decreases with, until the lift is equal to the weight of the float when immersed in a fluid, the float will stabilize at a certain height. The float position that corresponds to the size of the measured medium flow. A built-in magnet, the float with the medium moves up and down, with the movement of the float magnetic field changes.

        A, for in situ, by rotary magnetic float and the local indicator in the inner magnetic coupling, rotate, and drives the pointer, through the dial indicates the size of the flow.

        B, the intelligent, by a solid state magnetic sensor intelligent indicator in the magnetic field will change into electrical signal output by A/D transform, D/A microprocessor, LCD liquid crystal display to show the size and cumulative flow flow.

        Third, application:

        ZW-LZ series damping type metal tube rotameter has the advantages of simple structure, reliable operation, high accuracy, wide application range. Compared with glass rotor flowmeter can resist high pressure. With local indication, electric remote meter, limit switch alarm, corrosion resistance, damping and explosion-proof type jacket, etc.. Widely used in national defense, chemical, petroleum, metallurgy, electric power, environmental protection, medicine and other departments of the light liquid, gas flow measurement and automatic control.

        Four, structure:

        By 1, all metal structure, common type, high temperature, high pressure, damping type type type.

        2, according to the customer the pipe, the measuring tube structure can be divided into: in the cross, lower upper and lower transverse into cross, right into the left, the left into the right.

        3, this series of metal tube rotameter consists of 2 parts: the measuring tube and indicator. The measuring tube comprises a conical tube or plate, guide, stopper, float and other components, including magnetic indicator servo system, a pointer, a dial, lines and other components.

        Five, main features:

        1, all metal structure design, strong, simple, high pressure resistance, high temperature resistance, corrosion resistance, long service life;

        2, a short trip, the total height of 250mm, easy to install;

        3, mechanical pointer instructions LCD liquid crystal display instantaneous flow, instantaneous flow, cumulative flow;

        4, intelligent indicator, using foreign Zui new signal processing chip, modular design, no hysteresis;

        5, data recovery, data backup, power down protection and fault self diagnosis function;

        6, HART type indicator, two-wire 24VDC power supply, 4-20mA standard current signal output of HART protocol stack;

        7, through the HART communication manipulator configuration and parameters can be adjusted;

        8, with the PC serial connection, through the Windows program, to achieve on-site calibration of the instrument;

        9, can be used in flammable and explosive occasions;

        10, vertical and horizontal, upper lower, bottom side, side into the side such as the installation of a variety of forms, flange or threaded connection.

        Six, technical parameters:

        1, measurement range: water 2.5 ~ 100000l/h (20 C)

        2, range: 10:1

        3, 1.0, 1.5, precision grade: 2.5

        4, working pressure: DN15 DN25, DN50, PN4.0MPazui, DN80, DN100 10.0MPa PN1.6MPazui 6.4MPa

        5, medium temperature: -40 to 300 DEG C

        6, medium viscosity: DN15: <5mPa - s eta (F15.1 ~ F15.3)

        <30mPa - S (F15.4 - F15.8)

        DN25: <250mPa - s.

        DN50: <300mPa - S - DN150.

        7, the ambient temperature: LCD type: -40 to 85 DEG C

        Pointer type: -40 to 120 DEG C

        8, connection: flange (executive standard DIN2501 or as required by standard flange manufacturing)

        9 meter height: 250mm

        10, cable interface: M20*1.5

        11, power supply: 24VDC two-wire 4 ~ 20mA or 85 ~ 265VAC 50/60Hz (remote type)

        12, alarm output: alarm relay output lower or upper limit of instantaneous flow (contact capacity Zui 5A-250VAC) or open collector output (internal impedance Zui 100mA-30VDC 100 ohm).

        13, the cumulative output pulse: pulse output, Zui interval of every 10 seconds a pulse (AC) or a pulse every 50 milliseconds.

        14, double liquid crystal display: LCD display, display the instantaneous flow and cumulative flow.

        15: Exia II CT4, explosion-proof.

        16, the measuring tube material: 316 stainless steel (common type) or Teflon liner (corrosion type).

        Seven, structure classification:

        1, the high temperature structure (G type)

        High temperature structure type (G type) is used for medium temperature is too high or too low and the need to take measures on the insulation of the measuring tube medium flow measurement. The high temperature structure is increased and the distance between the measuring tube indicator to increase heat dissipation and increase the insulation thickness, ensure the working environment temperature indicator in the allowable range. The selection of the "G" type.

        The flow of G type metal tube flowmeter can measure the temperature of -80 DEG -+300 DEG medium.

        The structure of 2, with a damper device (Z type)

        Damper structure type flowmeter for entrance flow (pressure) medium flow measurement is unstable, especially for gas measurement.

        3, jacket type structure (T type)

        Jacket structure for heating or cooling of needs (such as high viscosity and flow measurement of the medium Yi Jiejing).In the jacket by heating or cooling medium, the fluid does not vaporize and crystallization.

        Import and export with thermal medium connection standard to use HG20594-97 DN15 PN1.6 flange, flange connection and other specifications may be marked with production plant, pressure rating jacket for 1.6MPa.

        Jacket structure size FA standard flow meter, flange type flowmeter.

        4, high pressure type structure (Y type)

        High pressure type structure for media pressure is greater than the standard pressure level measurement. At present, Zui high pressure can reach 32MPa. In addition high pressure type flowmeter can provide built-in magnetic filter type, installation height is 350mm. FA, FB and FC type Zui high pressure 10MPa.

        Eighth, conversion indicator:

        The converter is actually the height conversion taper pipe float into the corresponding volume scale. From the output signal: local display and remote signal output type:

        1, local display type: by in situ indicator in the follow-up magnetic float and the inner magnetic coupling, and rotate, and the electric pointer by dial indicating the flow

        2, intelligent remote type, by the intelligent indicator in the follow-up magnetic float and the inner magnetic coupling, rotate, and drives the magnet and the sensing pointer through a magnetic sensor magnetic field change into electrical signals by A/D conversion, digital filter, D/ microprocessor, A output, LCD liquid crystal display, to show the instantaneous flow and cumulative flow rate.

        Nine, product maintenance:

        1, in the process of long-term use, the pipeline inevitably there will be ferromagnetic impurity adsorption on the float, it will float stuck or affect the measurement accuracy, from time to time to clean the sensor float; if the installation of magnetic filters should be cleaned regularly.

        2, the instrument indicator with electronic components, instrument wiring or demolition of housing, to housing screws, must ensure sealing, prevent impurities, or other material into the water, and also to ensure reliable earthing of the meter casing.

        3, the instrument is installed, in use, should pay attention to:

        When the valve is opened to avoid the formation of pressure shock makes the float slamming limiting device, causing damage to the instrument, slowly open the valve!

        The measurement of gas meter is equipped with gas damper, Z to decrease the float concussion; to ensure the stability of the float, a throttle valve can be installed in the instrument export.

        4, for the remote type instrument, we must first ensure that the instrument wiring correctly, keeps power; for dangerous situations, must choose the explosion-proof, and the installation and use of proof required by the.

        Troubleshooting, fault:

        1, check the alarm set value size SU.

        2, check the deviation set D value can not be too large.

        3, FUN function, logic function is correct. HA-A said the upper limit is logical. LA-A said the lower limit is.

        4, circuit board failure, replace the board.

        5, if the lcd barcode indicates the correct output, no action, the cathode can check the external power and external power supply is connected with the anode of instrument power supply.

        If the wobble in use, according to the jitter amplitude to determine what kind of amplitude jitter. Divided into mild and moderate jitter jitter jitter and jitter.

        1, a slight jitter due to fluctuations caused by the media. Can be used to increase the damping of the way to overcome.

        2: general, moderate jitter caused by medium flow state. For general gas as the medium pressure instability caused by.The regulator or stabilizer to overcome or increase the damping of gas meter.

        3, severe jitter: mainly due to medium gas pulsation, operation pressure instability or give users pressure, temperature, flow meter and the actual state does not have large differences over range instrument.

        Eleven, the installation should follow the following steps:

        1, before installation to process piping, should remove all installed and checked for any transport damage;

        2, in order to prevent in transit, with a rubber band fixed pointer indicator, indicator should open the left cover it gently removed before connection, do not change the pointer position;

        3, open the indicator of the right cover, cable through the cable introducing device, according to the wiring diagram wiring rotation transmitter, pressure screw nut, the cable is fixed, and then tighten the fastening screws around the cover, the indicator of waterproof and dustproof;

        The upstream and downstream pipeline 4, instrument and instrument should be the same caliber, flange or threaded connection should be matched with the flange and screw instrument, instrument upstream straight pipe length should ensure that the instrument is 5 times the nominal diameter, downstream straight pipe length not less than H2 250mm;

        5, due to the use of the instrument measuring mechanism is magnetic transfer, so in order to ensure the performance of rotameter installed around the sensor, at least 100mm, the existence of ferromagnetic material is not allowed;

        6 before installation, instrumentation, piping should be purged, prevent the retention of ferromagnetic material in the pipeline is attached to the instrument, the instrument performance, or even damage the instrument. If unavoidable, should be installed at the entrance of the magnetic filter instrument;

        7, the measurement of gas meter is calibrated in special pressure, if the gas meter in the outlet directly discharged into the atmosphere, will produce a pressure drop in the float, and lead to data distortion. If this is the working conditions, should install a valve in the instrument exports, so that the required flow value is set, when the float to maintain calibration pressure, gas expansion in valve;

        The installation form 8, instrument installation for vertical and horizontal installation, if it is installed in a vertical straight form, should ensure that the instrument is better than 1%; if the level of installation form should ensure that the level of instrument is better than 1%;

        9, installed in the pipeline in the instrument should not be subject to stresses, the instrument should be a proper entrance and exit pipe support, can make the instrument in z stress state;

        10, product and computer related to calibration and other operations, must be in a safe place.

        Twelve, matters needing attention:

        In 1, before the first installation flowmeter in the pipeline, dirt, impurities such as welding blowing clean, if the liquid contained solid impurities, should the corresponding filter is installed between the valve and the straight pipe.

        2, shielding and grounding system: in order to ensure ideal electromagnetic compatibility, shielding and grounding is very important, especially the bus cable, cable as far as possible to make continuous shielding.

        3, the security zone, according to the requirements of conventional cable grounding as much as possible.

        4, in dangerous places, to ensure that the whole range of bus safe places and dangerous enough, all the potential, in this case, multiple ground is very superior.

        13, measuring range and pressure loss:

        Decay path

        Common path

        measuring range

        Zui high pressure loss

        DN (mm)

        DN (mm)

        The air (m3/h)

        Water (L/h)

        The air (KPa)

        Water (KPa)

        Fifteen

        Fifteen

        0.05-0.5

        1.6-16

        Seven

        Six point four

        0.07-0.7

        2.5-25

        Seven point one

        Six point five

        0.11-1.1

        4.0-40

        Seven point two

        Six point five

        0.18-1.8

        6.0-60

        Seven point three

        Six point six

        0.28-2.8

        10-100

        Seven point five

        Six point six

        0.40-4.0

        16-160

        Eight

        Six point eight

        0.70-7.0

        25-250

        Ten point eight

        Seven point two

        1.00-10

        40-400

        Ten

        Eight point six

        1.60-16

        60-600

        Fourteen

        Eleven point one

        Twenty-five

        -

        80-800

        -

        Fourteen

        Twenty-five

        3.00-30

        100-1000

        Seven point seven

        Seven

        4.50-45

        160-1600

        Eight point eight

        Eight

        7.00-70

        250-2500

        Twelve

        Ten point eight

        11-110

        400-4000

        Nineteen

        Fifteen point eight

        Fifty

        -

        500-5000

        -

        Sixteen point two

        Fifty

        18-180

        600-6000

        Eight point six

        Eight point one

        25-250

        1000-10000

        Ten point four

        Eleven

        Eighty

        40-400

        1600-16000

        Twelve point six

        Seventeen

        Eighty

        50-500

        2000-20000

        Fifteen point five

        Six point three

        One hundred

        75-750

        2500-25000

        Seventeen Point Two

        Eight point one

        One hundred

        100-1000

        4000-40000

        -

        Nine point five

        One hundred and twenty-five

        160-1600

        6000-60000

        -

        Ten

        One hundred and twenty-five

        250-2500

        8000-80000

        -

        Sixteen

        One hundred and fifty

        -

        10000-100000

        -

        Twenty


        300-3000

        12-120m3/h

        -

        Twenty


        400-4000

        15-150m3/h

        -

        Twenty-five

        14, encoding selection:

        Specification code

        Encoding instructions

        The name of the factory

        ZW

        Zhongwei control

        Instrument types

        LZ

        Metal tube rotameter

        structural style

        /

        In the next

        H1

        The left into the right

        H2

        Right into the left out

        AA

        The side into the side

        LA

        The bottom side

        S

        Threaded connection

        M

        Clamp connection (sanitary polishing tube)

        Size code

        - XXX

        Cases: Fifteen Express DN15

        The measuring tube material

        R1

        1Cr18Ni9Ti , Three hundred and four

        R0

        0cr18Ni12M02Ti , Three hundred and sixteen

        RL

        316L

        RP

        (PTFE F-lined )

        Ni

        (Hasloy Hastelloy C)

        Ti

        (TitHXium titanium alloy )

        Media type

        L

        liquid

        G

        Gas

          working temperature 

        H1

        - 40 C -100 C

        H2

        - 80 C -250 C

        Rated pressure

        One point six

        1.6MPa

        Four

        4.0MPa

        Sixteen

        16MPa

        Twenty-five

        25MPa

        Additional structure

        O

        nothing

        Z

        Damping type

        T

        Jacket

        H

        High temperature type

        Y

        High pressure type

        Form indicator

        M1

        Local indication

        M2

        Intelligent

        M3

        Intelligent ( Flameproof )

        The output signal in the communication

        N

        nothing

        A

        4-20mA

        H

        4-20mA+Hart

        Alarm controller

        K1

        The upper limit alarm

        K2

        Alarm

        K12

        The upper and lower limit alarm

        Explosion proof type

        E1

        Intrinsically safe EX IaCT5 Square shell

        E2

        Flameproof EXiibt4 Park Housing

        Power supply

        Zero

        24VDC (can be omitted )

        Two

        220VAC

        Three

        Three point six Volt lithium battery

        Fifteen, design selection and ordering information:

        1, please provide the pipe size, wall thickness, material requirements and accuracy requirements;

        2, please provide the liquid or gas, such as the name, commonly used commonly used temperature, working pressure, common flow, density, viscosity etc.;

        3, choose anti-corrosion type, should indicate the measured corrosion and concentration etc.;

        4, if there are special to show, please contact our sales department.

        Customer service service commitment:

        1, our series of metal tube flowmeter series product quality problems within twelve months, responsible for free maintenance.

        2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.

        3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.

        4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.

        5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


        Browse: