1. <dir id="mSLL8A"><q id="mSLL8A"></q></dir>

        Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

        Glass tube rotameter

        18玻瓈(li)筦轉(zhuan)子流(liu)量計01.jpg
        18玻瓈(li)筦(guan)轉子(zi)流量(liang)計(ji)03.jpg
        18玻(bo)瓈(li)筦轉子流量計02.jpg
        • 18玻瓈筦轉(zhuan)子(zi)流(liu)量(liang)計(ji)01.jpg
        • 18玻(bo)瓈(li)筦(guan)轉子流量(liang)計(ji)03.jpg
        • 18玻(bo)瓈(li)筦(guan)轉子流量(liang)計02.jpg
        ZW-LZB/LZJ series Glass tube rotameter According to its purpose and scope can be divided into: ordin…

        Description:

        Productoverview:

        ZW-LZB/LZJ series Glass tube rotameter According to its purpose and scope can be divided into: ordinary type, ribbed vascular type, small flow and low profile type, corrosion type, laboratory type, insulation type, alarm type and high pressure type eight series. According to the formulation of national instrument series, regardless of which Zui series, ranging from 1 to 100 mm in diameter and a total of 12 numbers, can measure the flow range: liquid (water) 0.1 ml / min to 40 cubic meters / hour, gas (air) 1 ml / min to 1000 cubic meters / hour. For environmental protection equipment of the glass rotameter is generally not more than 10 mm diameter, the flow measurement of small flow range.

        Two, work principle:

        ZW-LZB/LZJ series of glass tube rotameter is mainly composed of a bottom enlarged glass tube and a cone with the magnitude of fluid flow moves up and down the stainless steel float. The fluid flows through the cone bottom tube, buoyancy A fluid kinetic energy generated on the float lift S and fluid to float up, when the lift and buoyancy of A and S is equal to the gravity float G, float in the balance, stable at a certain height position, cone scale on the tube indicates that the fluid flow value.

        ZW-LZB- (F) for smooth wall cone tube flowmeter tube diameter meter above DN15, the float remained stable through the movement, the guide rod; ZW-LZJ- (F) three meter cone tube guide rib, the float remained stable. Through the meter diameter of DN10 or less connected by a hose, equipped with needle flow control valve; path DN15 flowmeter with flange connection.

        Three, application:

        ZW-LZB/LZJ series of glass tube rotameter is mainly used in chemical, petroleum, light industry, medicine, chemical fertilizer, chemical, food, dyestuff, environmental protection and scientific research departments, used to measure single-phase non pulsating (liquid or gas) fluid flow.

        Anticorrosion type is mainly used for the detection of corrosive liquid and gas medium flow, such as acid and alkali, oxidant, strong oxidizing acid, organic solvents and other corrosive gas or liquid medium flow detection.

        Four, main features:

        1, small pressure loss. In the process of using, can be fully utilized, without a lot of effort too much, all the pressure can be fully used, there will be no loss.

        2, reliable performance. Glass rotor flowmeter in operation, frequent failure will not ensure good operation. When people are in the process of using, don't worry about running for it. Good performance, high reliability, can be assured use.

        3, simple structure, convenient installation and use. The structure of the glass rotameter is simple, the installation is very convenient, can be installed in a short period of time.

        Fifth, technical parameters:

        1, size: DN2 ~ 100mm;

        2, measuring range: water (20 C): 1L/h ~ 100m3/h, gas (101325Pa, 20 C): 16L/h ~ 3000m3/h;

        3, the range ratio: 10: 1;

        4, precision grade: grade 1.5, grade 2.5, grade 4;

        5, nominal pressure: DN4 ~ 10 1.0MPa, 50 0.6MPa, DN15 ~ DN80 ~ 100 0.4MPa;

        6, working temperature: less than or equal to 120 DEG c;

        7, connection: hose, metal pipe, flange (GB/T9119-2000);

        8, material: flange, float, a guide rod, a supporting plate and bolts are made of stainless steel 304 (1Cr18Ni9Ti), type LZB-B.

        Note: the wetted materials for use in 316, is a model for the LZB-Bo, can be customized.

        For stainless steel PTFE is type LZB-BF (or BoF), can be customized.

        Six, selection method:

        1, measurement. Measuring the media type, size, pressure and chemical properties. Such as liquid and gas medium, the corrosive medium should choose corrosion resistance meter.

        2, the performance of flowmeter. The above conditions are identified in general, if the price is no big change, may be preferred needle valve is arranged on the upper part of the large circulation flow meter; hole, direct flow scale; simple structure; small exterior dimensions etc.. Such as small flow range, you can choose to use the ball float type, because of its measurement stability, not easy dust, high precision, good interchangeability.

        The price of 3, according to the. Generally speaking, the high price of high precision. According to the measurement instruments such as precision grade, only through the medium of control measure, the operation adjustment, after always stabilize the throughput, so the accuracy is minor.

        Seven, matters needing attention:

        1, don't put the front cover removed, because the glass tube easy blasting, shell to protect.

        2, when used in winter, should pay attention to keep warm, if the night is not used, the residual liquid in the flow discharged, so as not to freeze broken glass tube.

        3, to the pipeline installation, first look at the downstream pipeline is in a straight line. If not in a straight line, will not only affect the measuring accuracy of the instrument, but also will damage the flowmeter.

        4, when the valve is opened, will slowly open, if the estimated flow to floating rotor, and the rotor does not move up, immediately stop valve, tap the pipeline, so that the rotor can slowly rise.

        5, first observed within the flow tube is intact, glass tube is easy to damage; second is to remove the rotor fixture, gently slide backward to see whether the rotor freely up and down. If not free to slide, vibration plate gently. If we can not slide, would need professional solutions.

        Eight, specifications and measuring range:

        1, ordinary type:

        LZB-2

        LZB-3

        Model

        LZB-4

        LZB-6

        LZB-10

        Phi 2

        Phi 3

        Nominal diameter mm

        Phi 4

        Phi 6

        Phi 10

        Less than or equal to 1

        Less than or equal to 1

        The working pressure of MPa

        Less than or equal to 1

        Less than or equal to 1

        Less than or equal to 1

        + 4

        + 4

        Basic error limit%

        + 4

        + 2.5

        + 2.5

        1:10

        1:10

        The scope of

        1:10

        1:10

        1:10

        0.4~4

        2.5~25

        liquid
        Ml/min

        measuring range

        liquid
        L/h

        1~10

        2.5~25

        6~60

        0.6~6

        4~40

        1.6~16

        4~40

        10~100

        1~10

        6~60

        2.5~25

        6~60

        16~160

        1.6~16

        10~100

        6~60

        40~400

        Gas
        Ml/min

        Gas
        L/h

        16~160

        40~400

        100~1000

        10~100

        60~600

        16~160

        100~1000

        25~250

        60~600

        160~1600

        25~250

        160~1600

        40~400

        100~1000

        250~2500

        2, ordinary type:

        Model

        LZB-15

        LZB-25

        LZB-40

        LZB-50

        LZB-80

        LZB-100

        Nominal diameter

        Phi 15

        Phi 25

        Phi 40

        Phi 50

        Phi 80

        Phi 100

        Ratio measurement

        1:10

        1:10

        1:10

        1:10

        1:5 1:10

        1:5

        Working pressure

        Less than or equal to 0.6

        Less than or equal to 0.6

        Less than or equal to 0.6

        Less than or equal to 0.6

        Less than 0.4

        Less than 0.4

        Precision grade

        Two point five

        One point five

        One point five

        One point five

        One point five

        One point five

        Flow range

        liquid

        (m3/h)

        16-160 (L/h)

        40-400 (L/h)

        0.16-1.6

        0.4-4.0

        1-10

        5-25

        25-250 (L/h)

        60-600 (L/h)

        0.25-2.5

        0.6-6.0

        1.6-16

        8-40

        40-400 (L/h)

        100-1000 (L/h)





        Gas

        (NM3/h)

        0.25-2.5

        1-10

        4-40

        10-100

        50-250

        120-600

        0.4-4.0

        1.6-16

        6-66

        16-160

        80-400

        200-1000

        0.6-6.0

        2.5-25





        3, corrosion resistance:

        Model

        LZB-15F

        LZB-25F

        LZB-40F

        LZB-50F

        LZB-80F

        LZB-100F

        Nominal diameter

        Phi 15

        Phi 25

        Phi 40

        Phi 50

        Phi 80

        Phi 100

        Ratio measurement

        1:10

        1:10

        1:10

        1:10

        1:5 1:10

        1:5

        Working pressure

        Less than or equal to 0.6

        Less than or equal to 0.6

        Less than or equal to 0.6

        Less than or equal to 0.4

        Less than or equal to 0.4

        Less than or equal to 0.4

        Precision grade

        Four

        Two point five

        Two point five

        Two point five

        Two point five

        Two point five

        Flow range

        liquid

        (m3/h)

        16-160 (L/h)

        40-400 (L/h)

        0.16-1.6

        0.4-4.0

        1-10

        5-25

        25-250 (L/h)

        60-600 (L/h)

        0.25-2.5

        0.6-6.0

        1.6-16

        8-40

        40-400 (L/h)

        100-1000 (L/h)





        Gas

        (NM3/h)

        0.25-2.5

        1-10

        4.0-40

        10-100

        50-250

        120-600

        0.4-4.0

        1.6-16

        6.0-66

        16-160

        80-400

        200-1000

        0.6-6.0

        2.5-25





        4, LZB-S:

        Model

        LZB-15S

        LZB-25S

        LZB-50S

        LZB-80S

        Nominal diameter mm

        Phi 15

        Phi 25

        Phi 50

        Phi 80

        The working pressure of MPa

        Less than or equal to 0.6

        Less than or equal to 0.6

        Less than or equal to 0.6

        Less than 0.4

        The basic error indication limit%

        + 2.5

        + 2.5

        + 2.5

        + 2.5

        measuring range

        Liquid L/h

        4~90

        70~700

        450~7000

        7000~30000

        Stainless steel
        Flanges, a float, a guide rod, a supporting plate and bolts are made of stainless steel 304 (1Cr18Ni9Ti), type ZW-LZB- (B).
        Wetted materials such as the need to use 316, then type ZW-LZB- (Bo), can be customized.
        For stainless steel PTFE is type ZW-LZB- (BF) (or BoF), can be customized.
        PTFE type
        Base, float, needle with polytetrafluoroethylene (PTTFE). Support plate and screws made of stainless steel.

        Nine, appearance and installation dimensions:

        Table 1,

        Path

        The size (mm)

        A

        B

        C

        D

        E

        Two

        One hundred and ten

        One hundred and thirty-two

        One hundred and fifty

        M8 * 1

        31 x 26 (front)

        Three

        One hundred and ten

        One hundred and thirty-two

        One hundred and fifty

        M8 * 1

        31 x 26 (front)

        Four

        One hundred and seventy

        Two hundred and eight

        Two hundred and thirty-eight

        Phi 11

        40 x 34 (front)

        Six

        One hundred and seventy

        Two hundred and eight

        Two hundred and thirty-eight

        Phi 11

        40 x 34 (front)

        Ten

        One hundred and seventy

        Two hundred and eight

        Two hundred and thirty-eight

        Phi 11

        40 x 34 (front)

        Table two:

        Diameter (mm)

        The size (mm)

        A

        B

        C

        D

        E

        Fifteen

        Phi 95

        Phi 65

        Four hundred and seventy

        Phi 15

        With the diameter of 14 4-

        Twenty-five

        Phi 105

        Phi 78

        Four hundred and seventy

        Phi 25

        With the diameter of 14 4-

        Forty

        Phi 145

        Phi 110

        Five hundred and seventy

        Phi 40

        With the diameter of 18 4-

        Fifty

        Phi 160

        Phi 125

        Five hundred and seventy

        Phi 50

        With the diameter of 18 4-

        Eighty

        Phi 185

        Phi 150

        Six hundred and sixty

        Phi 80

        With the diameter of 18 4-

        One hundred

        Phi 205

        Phi 170

        Six hundred and sixty

        Phi 100

        With the diameter of 18 4-

        10, encoding selection:

        ZW-LZB

        -

        caliber

        function

        Description (Zhongwei control)



        DN2-100


        caliber


        No label

        Ordinary type

        F

        Corrosion proof type, PTFE base (for DN2~DN10) or carbon steel flange lining PTFE

        B

        All stainless steel material: 304 stainless steel

        B0

        All stainless steel material: 316 stainless steel

        F/B (B0)

        Type: stainless steel corrosion-resistant stainless steel flange (304 or 316) lined with PTFE (for DN15~DN100)

        ZW-LZB

        -

        .

        .

        Glass tube flowmeter

        Common type: mainly applicable to non corrosive medium measurement;

        Corrosion proof type: mainly suitable for corrosive medium measurement;

        All stainless steel type: mainly applicable to sanitary and weak corrosive medium measurement, can anti corrosive gas environment for use in;

        Stainless steel corrosion proof type: mainly suitable for corrosive media measurement, can anti corrosive gas environment in use.

        Eleven, ordering:

        1, according to the measurement of the fluid is a gas or liquid, the correct selection of ZW-LZB rotor flowmeter.

        2, the measured fluid is non corrosive with ordinary type, corrosive resistant type selection.

        3, please specify when ordering the names, the measured flow rate, pipe diameter and pressure, temperature, density, viscosity, etc.. According to the user's density of correction, making special flow gauge.

        4, according to the measurement range and measured fluid applications such as choosing the suitable type of the specifications. As the special requirements of the flowmeter, or call the sales department, and company.

        Customer service service commitment:

        1, our series of flowmeter series product quality problems within 12 months, responsible for free maintenance.

        2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.

        3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.

        4, the warranty period after the product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.

        5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


        Browse:
        Return To The Top

        分亯到:

        rhxXh

        1. <dir id="mSLL8A"><q id="mSLL8A"></q></dir>