        Thermal sleeve type double metal thermometer

        5熱套(tao)式(shi)雙(shuang)金屬(shu)溫(wen)度(du)計.jpg
        • 5熱(re)套(tao)式(shi)雙金(jin)屬溫(wen)度(du)計.jpg
        WSS series Thermal sleeve type double metal thermometer Is a kind of field measurement for middle an…

        Description:

        Productoverview:
        WSS series Thermal sleeve type double metal thermometer Is a kind of field measurement for middle and low temperature measuring instrument, can be used for direct measurement of gas, liquid, and vapor temperature. The thermometer from the design principle and structure of waterproof, anti-corrosion, explosion-proof, anti vibration, intuitive, easy reading, no mercury damage, durability and other characteristics. The measurement instrument can replace the other workers.
        Two, work principle:
        WSS series Thermal sleeve type double metal thermometer Is the principle of expansion work in varying degrees of temperature change when using two different metals. Industrial use of double metal thermometer main element is one with two or more metal sheet laminated together to form a multilayer metal sheet. In order to improve the measurement sensitivity of double metal thermometer, usually made of sheet metals of spiral shape. When the multilayer metal sheet temperature changes, each layer of metal expansion or shrinkage range, so that the spiral rolled up or loosen. Since the end of the spiral coil is fixed and the other end and a pointer can rotate freely. Therefore, when the feeling of double sheet metal to temperature changes, in a pointer to the circular indexing on the gauge indicates the temperature to.
        Three, application:
        WSS series Thermal sleeve type double metal thermometer With the installation of all kinds of casing, meet different pressure level requirements. Can be directly measured in various production processes within the range of -80-+500 DEG C liquid, steam and gas and solid surface temperature.
        Four, main features:
        1, the scene display temperature, convenient, safe and reliable, long life and other characteristics.
        2, victims of mercury free, easy reading, strong shock.
        3, the protection pipe of 1Gr18Ni9Ti stainless steel and two molybdenum titanium, pressure, strong corrosion resistance.
        4, core pulling type thermometer can not stop short time maintenance or replacement of movement.
        Five, technical parameters:
        The implementation of standards
        JB/T8803-1998 GB3836-83.
        Other parameters
        Dial diameter: 60100150;
        The accuracy level: (1, 1.5);
        Thermal response time: less than 40S;
        Protection grade: IP55;
        Angle adjusting error: angle adjusting error should not exceed the range of 1.0%;
        Return difference: double metal thermometer to the difference should be less than the absolute value of the basic error limit;
        Repeatability: double metal thermometer repeatability limit should be less than the absolute value of basic error of 1/2.

        Six, matters needing attention
        1, can not be directly screw head;
        2, the length of choice to choose the standard size close to the (integer multiples of 50mm);
        3, the protective tube immersionmedium measured in length must be greater than the length of the sensing element, the general recommended immersion length is greater than 100mm, 0-50 DEG C immersion length range is more than 150mm, to ensure the accuracy of measurement.
        4, double metal thermometer should not be used to open the container medium temperature measurement.
        In 5, storage, installation and transportation, should avoid collision protection tube, do not allow the protection tube bending change, but not the table when using the wrench.
        6 regular inspection, under normal conditions of use should be. In general, every six months.
        7, not allowed to work in the strong vibration environment, so as not to affect the double metal life, electric contact bimetallic thermometer is not allowed in the control loop vibration occasions, so as not to affect the reliability.

        Seven, temperature range:

        The measuring range of C

        Applicable scope

        Industrial and commercial

        Laboratory and small

        -80 ~ +40

        B.

        B.

        -40 ~ +80

        B.

        B.

        0~50

        B.

        B.

        0~100

        B.

        B.

        0~150

        B.

        B.

        0~200

        B.

        B.

        0~300

        B.

        B.

        0~400

        B.

        B.

        0~500

        B.

        B.

        Eight, dimensions:

        form

        D

        A

        B

        E

        D

        Radial type

        One hundred and five

        Twenty-three

        Seventy-three


        With 8

        With 10

        One hundred and fifty-five

        Twenty-three

        Seventy-three


        Axial type

        Sixty-five

        Fifty

        One hundred and ten

        Thirty-four

        One hundred and five

        Fifty

        One hundred and ten

        Thirty-four

        Universal type

        One hundred and five

        Twenty-three

        One hundred and seventy-eight

        One hundred and twenty

        One hundred and fifty-five

        Twenty-three

        One hundred and seventy-eight

        One hundred and twenty

        Electric contact

        Axial type

        One hundred and twenty-eight

        Forty

        One hundred and thirty-five


        Electric contact

        Radial type

        One hundred and twenty-eight

        Seventy-two

        One hundred and fifty

        Forty-two

        Electric contact

        Universal type

        One hundred and twenty-eight

        Forty

        One hundred and seventy-five

        Ninety-eight

        9, models and specifications:

        Model

        Measuring range

        Precision grade

        Protection tube material

        Specifications

        Nominal pressure

        Casing form

        WSS-403S

        -80-+40

        -40-+80

        0-50

        0-100

        0-150

        0-200

        0-300

        0-400

        0-500

        1, 5

        1Cr18Ni9Ti

         

        Three hundred and four

        Three hundred and sixteen

        316L

        Hastelloy C-276

        Seventy-five

        One hundred

        One hundred and fifty

        Two hundred

        Three hundred

        Less than 30MPa

        Threaded connection

        WSS-503S

        WSS-413S

        WSS-513S

        WSS-483S

        WSSX-413S

        WSSX-483S

        WSS-403L

        150-40MPa

        Flange type

        WSS-503L

        WSS-413L

        WSSX-503L

        WSS-483L

        WSS-583L

        WSSX-403L

        WSSX-483L

        Note: Zhongwei and double metal thermometer can be installed with a variety of casing, casing in thermal heat installation form installation casing;
        The protection tube material according to ordering protocol: * said nominal pressure set according to flange pressure rating.

        10, encoding selection:

        Serial number

        WSS


        Double metal thermometer (Zhongwei control)

        Dial diameter

        -3


        Phi 60

        -4


        Phi 100

        -5


        Phi 150

        Dial form

        Zero


        The axial (straight)

        One


        Radial (angle)

        Two


        135 degrees to (an obtuse type)

        Eight


        Universal (angle adjustable type)

        Fixed form

        Zero


        No fixed device

        One


        Movable external thread

        Two


        The movable internal thread

        Three


        Fixed thread

        Four


        Fixed flange

        Five


        Card set screw

        Six


        Sleeve flange

        Type of protection

        S

        L

        Heat (S for screw type and type L flange type)

        W


        Type of protection

        F


        Anti-corrosion type

        The selection of examples:
        Universal type double metal thermometer, dial diameter 100, temperature range of 0 to 400 DEG C, 1.5, M27 * 2 rotatablemale thread length 450mm, WSS-481, 0 ~ L=450, 400 C, M27 * 2, 1.5.

        The design and selection of notes:

        1, model;
        2, precision grade;
        3, temperature range;
        4, fixed form;
        5, the installation form of casing heat;
        6, the inserted length.
        Customer service service commitment:
        1, my company sold Zhongwei Thermometer series The product within twelve months of quality problems, responsible for free maintenance.
        2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
        3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
        4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
        5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


        Browse: