1. <dir id="mSLL8A"><q id="mSLL8A"></q></dir>

        Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
        0517-86918678
        Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
        Tel:0517-86918678
        Fax:0517-86918679
        Email:zhongweick@https://zhanhaojiuye.com
        Post Encoding:211600

        The thermal resistance of remote bimetal thermometer

        5電(dian)阻(zu)遠(yuan)傳雙(shuang)金屬(shu)溫(wen)度(du)計.PNG
        • 5電(dian)阻(zu)遠(yuan)傳(chuan)雙(shuang)金屬溫度(du)計(ji).PNG
        WSSP series The thermal resistance of remote bimetal thermometer And the development of a series of …

        Description:

        Productoverview:
        WSSP series The thermal resistance of remote bimetal thermometer And the development of a series of temperature instruments, to overcome the traditional thermometer single expansion performance and short service life and poor reliability, the disadvantages of large volume temperature package. The temperature sensor of steam and gas volume respectively than the traditional pressure type thermometer reduced by 30 and 60 times, creatively or platinum copper heat resistance temperature sensor mounted on the measuring element, realize the function of temperature measurement of electromechanical integration. Formed by the liquid pressure type temperature is extremely basic temperature measuring instrument for remote transmission, explosion-proof, anti-corrosion, shockproof, electrical connector, temperature signal transmission and other functions, a series of temperature meter.

        Two, work principle:
        WSSP series The thermal resistance of remote bimetal thermometer Is a kind of thermal resistance temperature sensor and WSSP type thermometer temperature package installed in the same temperature element within a temperature measuring instrument. Two measurement systems are independent of each other, do not affect the temperature measurement accuracy and their. The outstanding advantages of this instrument is just a single point temperature measurement can double indicate the measured temperature, the pressure for the instructions, the thermal resistance signal for transmission to the control room (about 500 meters), with two meter line, to control and adjust the measured temperature, the two temperature measurement system to monitor each other, improve the temperature measurement accuracy and reliability.
        Three, application:
        WSSP series The thermal resistance of remote bimetal thermometer Not only meet the temperature requirements, but also to meet the needs of long-distance transmission, remote double metal thermometer can directly measure the production process in a variety of -40 ~ +600 temperature range of liquid, gas and steam medium and solid surface temperature measurement.
        Four, main features:
        1, a temperature probe of small, high sensitivity, linear scale, long service life etc..
        2, with remote output resistance signal (PT100), shock resistance, corrosion resistant function and large power switch signal etc..
        3, structure and international similar products, can replace imported.
        Five, technical parameters:
        1, the temperature range of -40 to 600 DEG c;
        2, the ambient temperature of -10 to 55 DEG c;
        3, the relative humidity is less than or equal to 95%;
        4, precision grade 1.5;
        5, the time constant is less than or equal to 60S;
        6, the probe voltage is less than or equal to 6Mpa;
        7, probe diameter: 8-10mm diameter, movable external thread: M27*2;
        8, thermal resistance PT100 (single channel, dual output or 4-20mA output current).

        Six, matters needing attention:
        1, in storage, installation, use and transport process, to avoid the collision protection tube, prohibit the protection tube bending and deformation.
        2, installation, non twist instrument shell.
        3, the instrument shall work normally in the -30 to 80 DEG C ambient temperature.
        4, the instrument can often work in the temperature scale range 1/2 ~ 3/4.
        5, the protective tube immersionmedium measured in length must be greater than the length of the sensing element, this is done in order to ensure the accuracy of measurement.
        6, do not use media exposure in measuring container.
        7, the use of the process should pay attention to check in time, probably in about 6 months.

        Seven, technical data sheet: 

        type Number

        Graduation

        The measuring range of C

        Precision grade

        Protection tube material

        Insertion length

        WSSE-401

        E

        -80 ~ +40

        Forty ~+80

        Zero ~Fifty

        Zero ~One hundred

        Zero ~One hundred and fifty

        Zero ~Two hundred

        Zero ~Three hundred

        Zero ~Four hundred

        Zero ~Five hundred

        One point five

        1Cr18Ni9Ti

        Three hundred and four ;

        Three hundred and sixteen; 

        316L ;

        Harrington

        C-276

        One hundred and fifty

        Two hundred

        Three hundred

        Four hundred

        Five hundred

        Seven hundred and fifty

        One thousand

        WSSE-501

        WSSE-411

        WSSE-511

        WSSE-481

        WSSE-581

        WSSP-401

        Pt100

        WSSP-501

        WSSP-411

        WSSP-511

        WSSP-481

        WSSP-581

        WSSXE-401

        E

        WSSXP-401

        Pt100

        WSSXE-411

        E

        WSSXP-411

        Pt100

        WSSXE-481

        E

        WSSXP-481

        Pt100

        Eight, temperature range:

        The measuring range of C

        Applicable scope

        Industrial and commercial

        Laboratory and small

        -80 ~ +40

        B.

        B.

        -40 ~ +80

        B.

        B.

        0~50

        B.

        B.

        0~100

        B.

        B.

        0~150

        B.

        B.

        0 ~ 200

        B.

        B.

        0 ~ 300

        B.

        B.

        0~400

        B.

        B.

        0~500

        B.

        B.

        Remarks:
        One The insertion depth of the thermometer, L Must be greater than Lmin , L Alternative series: One hundred , One hundred and fifty , Two hundred , Two hundred and fifty , Three hundred , Four hundred , Five hundred , Seven hundred and fifty , One thousand , One thousand two hundred and fifty , One thousand and five hundred , Two thousand So, also can be customized according to user needs.
        Two And the protective tube diameter Phi 6 , Phi 8 The series of thermometers, the time constant is less than Forty Second, diameter Phi 10 When the time constant is less than Thirty Seconds.
        Three Protect the stainless steel tube 1Cr18Ni9Ti Manufacturing, at room temperature under high working pressure is Zui 6.4MPa .

        Nine, shape and size:

        structural style

        A

        B

        C

        E

        L

        D

        The axial type double metal thermometer

        Sixty-five

        Twenty-three

        Seventy-three

        -

        Seventy-five
        One hundred
        One hundred and fifty
        Two hundred
        Three hundred
        Four hundred
        Five hundred
        Seven hundred and fifty
        One thousand

        Phi 6
        Phi 8
        Phi 10

        One hundred and five

        Twenty-three

        Seventy-three

        -

        One hundred and fifty-five

        Twenty-three

        Seventy-three

        -

        The radial type double metal thermometer

        Sixty-five

        Fifty

        One hundred and ten

        Thirty-four

        One hundred and five

        Fifty

        One hundred and ten

        Thirty-four

        One hundred and five

        Fifty

        One hundred and ten

        Thirty-four

        135 degrees to type double metal thermometer

        One hundred and five

        Twenty-three

        Eighty-five

        -

        One hundred and fifty-five

        Twenty-three

        Eighty-five

        -

        Universal type double metal thermometer

        One hundred and five

        Twenty-three

        One hundred and seventy-eight

        One hundred and twenty

        One hundred and fifty-five

        Twenty-three

        One hundred and seventy-eight

        One hundred and twenty

        Ten, the selection of encoding:

        Serial number

        category

        Specifications

        Explain

        WSS

        P

        Thermal resistance type

        Double metal thermometer (Zhongwei control)

        Dial diameter

        -3


        Phi 60

        -4


        Phi 100

        -5


        Phi 150

        Dial form

        Zero


        The axial (straight)

        One


        Radial (angle)

        Two


        135 degrees to (an obtuse type)

        Eight


        Universal (angle adjustable type)

        Fixed form

        Zero


        No fixed device

        One


        Movable external thread

        Two


        The movable internal thread

        Three


        Fixed thread

        Four


        Fixed flange

        Five


        Card set screw

        Six


        Sleeve flange

        Type of protection

        -


        Ordinary type

        W


        Type of protection

        F


        Anti-corrosion type

        Cases: The axial type, PT100 type, I temperature range of 0-400 DEG c.. Activity thread M27x2, protective tube insertion length is 316 300mm. WSSP-401 0-400 l=300mm I: C protection tube 316.

        The design and selection of notes:
        1, model;
        2, the thermal resistance index number;
        3, the thermal resistance precision grade;
        4, double metal thermometer precision grade;
        5, temperature range;
        6, fixed form;
        7, protection tube material;
        8, the inserted length.
        Customer service service commitment:
        1, my company sold Zhongwei Thermometer series The product within twelve months of quality problems, responsible for free maintenance.
        2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
        3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
        4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
        5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


        Browse:
        Return To The Top

        分(fen)亯到:

        kbCAS

        1. <dir id="mSLL8A"><q id="mSLL8A"></q></dir>