        High temperature noble metal thermocouple

        9高(gao)溫貴金屬(shu)熱電偶.jpg
        • 9高(gao)溫(wen)貴金屬(shu)熱電(dian)偶.jpg
        WRP series High temperature noble metal thermocouple Divided into three types: S type thermocouple (…

        Description:

        Productoverview:

        WRP series High temperature noble metal thermocouple Divided into three types: S type thermocouple (10- platinum and Rhodium Platinum thermocouple), R type thermocouple (13- platinum and Rhodium Platinum thermocouple), B type thermocouple (30- platinum rhodium 6 thermocouple), mainly divided into single and double platinum rhodium, applicable to all kinds of high temperature, is widely used in the production process of glass, ceramics and other industrial salt bath furnace in the temperature measurement. The S type thermocouple is currently one of the most commonly used industrial. Due to the measurement of high temperature, high temperature resistant stainless steel protection tube generally only up to 1000 degrees, 1000 degrees above the resistance of stainless steel protective tube is expensive, it is commonly used in corundum ceramic protection tube, high purity corundum tube can withstand high temperatures up to 1600 degrees, the disadvantage is fragile.

        Two, work principle:

        WRP series <strong> high temperature noble metal thermocouple</strong> is composed of two different components of the conductor is connected to the two ends of the synthetic circuit, when the two junction temperature at the same time, will be in the heat generated within the current loop. If the working end and the reference thermocouple endthere is atemperaturedisplay, will be a corresponding display instrument instructions from thermocouples thermoelectric temperature value.

        Three, the main part of:

        WRP series high temperature thermoelectric noble metal thermocouple heat will increase with increase of temperature measurement terminal, its sizeonly withthermocouple materials and ends of the temperature, and thermal electrode length and diameter of the independent. All kinds of rhodium thermocoupleappearanceoftenbecause the needs and not the same, but their basic structures are roughly the same, usually composed of a thermal insulating sleeve, electrode protection tube and terminal box main components.

        Four, application:

        WRP series high temperature noble metal thermocouple made of precious metal of high pure platinum as anode and platinum rhodium alloy as cathode, suitable for high temperature applications in various production processes, widely used in powder metallurgy sintering, bright furnace, vacuum furnace, smelting furnace, glass, ceramics andindustrialfurnaceandsalt bath furnace temperature.

        Five, technical parameters:

        Thermocouple is a kind of traditional temperature measuring element with thermoelectric stable performance, strong oxidation resistance, suitable for continuous use in oxidizing and inert atmosphere. The long-term use temperature of 1600 DEG C, short term use temperature of 1800 DEG C. The technical indicators are as follows:

        1, the temperature range of 0~1800 DEG c;

        2, measurement accuracy: < + 0.5% t;

        3, time constant: less than 180s;

        4, insulation resistance: 5M ohm (20 C);

        5, size: 50075010001200 (mm).

        Six, measurement of temperature and tolerance:

        Thermocouple typeCodeGraduationMaximum temperatureTemperature measurementThe allowable deviation of T C
        30- platinum rhodium 6WRRB0~18000-1600C + 0.25%t or + 1.5
        10- platinum rhodiumWRPS0~16000-1300C + 0.25%t or + 1.5
        Nickel chromium nickel siliconWRNK0~13000-1100C + 0.75%t or + 2.5
        Nickel - chromiumWREE0~8000-800C + 0.75%t or + 2.5

        Seven, models and specifications:

        ModelGraduationThe measuring range of CProtection tube materialThermal response timeSpecifications
        DL x L
        WRP-130
        WRP2-130
        S0-1300High alumina< 150SPhi 16300x150
        350x200
        400x250
        450x300
        550x400
        650X500
        900x750
        1150x1000
        1650x1500 2150x2000
        WRP-131
        WRP2-131
        < 360SPhi 25
        WRQ-130
        WRQ2-130
        R0-1300< 150SPhi 16
        WRQ-131
        WRQ2-131
        < 360SPhi 25
        WRR-130
        WRR2-130
        B0-1600Corundum tube< 150SPhi 16
        WRR-131
        WRR2-131
        < 360SPhi 25

        Eight, Selection code:

        WRSpecificationsContent (Zhongwei control)


        R
        30- platinum rhodium 6
        P
        10- platinum rhodium
        N
        Nickel chromium nickel silicon
        E
        Nickel - chromium (chromium Constantan)
        heat
        electric
        even
        material
        material
        -One
        No fixed device
        Two
        Fixed screw type
        Three
        Movable flange
        Four
        Fixed flange
        Five
        A movable flange square form
        Six
        Fixed thread taper protection tube
        Fixed formTwo
        Splash proof
        Three
        Waterproof type
        Four
        Flameproof type
        Connection boxZero16mm protection tube
        One25mm protection tube (double casing)
        Two16mm high aluminum tube (single tube)
        Three20mm high aluminum tube
        DesIgn Serial Number.
        WR.-....

        Nine, Design selection and ordering information:
        Please provide the indexing number, precision grade, fixed form, protection material, length or depth of insertion tube (protective tube length L=l+150, special insertion depth and protection tube material can be ordered according to the agreement).
        Customer service service commitment:
        1, I sold by the company Thermocouple series The product within twelve months of quality problems, responsible for free maintenance.
        2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
        3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
        4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
        5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.



        Browse:
        Return To The Top

        分亯(xiang)到:

        ggnkT

        1. <dir id="mSLL8A"><q id="mSLL8A"></q></dir>