        Explosion-proof thermal resistance

        6防爆(bao)型(xing)熱(re)電阻(zu)(灋(fa)蘭(lan)式)01.png
        • 6防爆(bao)型熱電(dian)阻(灋蘭式(shi))01.png
        WZP-240 series Explosion-proof thermal resistance The structure, principle and assembly of thermal r…

        Description:

        Productoverview:

        WZP-240 series Explosion-proof thermal resistance The structure, principle and assembly of thermal resistance is basically the same, the difference is, flameproof or intrinsically safe explosion-proof junction box products (shell) special structure is adopted in the design, wiring box with high strength Aluminum Alloy die casting, and has sufficient internal space, wall thickness and mechanical strength, thermal stability of rubber seal the rings are in line with national standards. So, when the explosive mixed gases inside the enclosure when the explosion occurred, the internal pressure will not destroy the junction box, and the resulting heat is not the outward diffusion of detonation.

        Two, work principle:
        WZP-240 series Explosion-proof thermal resistance The gap explosion-proof junction box component design principle, with sufficient strength, all can produce a spark, arc and dangerous temperature components are sealed in a box cavity, when the cavity when the explosion occurred, the joint gap flameout and cooling, so that the explosion flame and temperature transmission to the outside of the cavity, thereby temperature measurement.
        Three, application:
        WZP-240 series Explosion-proof thermal resistance Usually, record and display instruments using instruments, electronic computing and other supporting. Direct measurement of hydrocarbons in the production site and other explosives -200 ~ C~500 ~ C range of liquid, steam and gas and solid surface temperature.
        Four, main features:
        1, various forms of explosion-proof, explosion-proof performance;
        2, large measuring range;
        3, high mechanical strength, good pressure resistance.
        4, a spring type temperature sensing element, good seismic performance;
        Five, technical parameters:
        Product executive standard
        IEC751
        JB/T18622-1997
        JB/T8623-1997
        JB/T5518-91
        Insulation resistance at room temperature
        Heat resistance at ambient temperature is 15 to 35 DEG C, relative humidity is less than 80%, the test voltage is 10 - 100V (DC) >100M. The insulation resistance between electrode and outer tube.

        Six, installation method:
        1, first of all should measure the good thermal resistance thread thread or flange size, supporting flange or thread processing base.
        2, according to the size of the base flange or threaded hole in the pipe, to be measured.
        3, the flange or the screw tooth of the welding. The flange or thread is inserted has opened hole in the flange or threaded seat base and pipeline measured welding.
        4, the screw base thermal resistance with bolts or threaded in has been welded.
        5, in accordance with the wiring diagram of the terminal box thermal resistance grounding line, and the display instrument is connected on the dial corresponding. Connection box can not contact with the wall of the measured medium pipeline, ensure the junction box temperature not exceeding 100 DEG C. Outlet hole junction box should prevent due to poor sealing water vapor, dust deposition caused by short circuit terminal.

        Seven, measurement range and tolerance:

        Model

        Graduation

        The temperature range of C DEG

        Precision grade

        Tolerance

        WZP240

        Pt100

        -200-+500

        A

        (0.15+0.002 + LTL)

        WZC240

        Pt100

        -200-+500

        B

        (0.30+0.005ltl).

        Eight, selection table:

        Code

        WZ - - - - - - - - - - - - - / - armored thermal resistance

        W

        Temperature meter (Zhongwei control)


        Code


        Z

        Heat resistance


        Code

        The temperature measuring element

        P

        Pt100 Pt1000 (the order required)

        C

        Cu50


        Code


        K

        Armoured type (assembled the symbol)


        Code



        Single

        Two

        Double branch


        Code

        Installation assembly (armoured)

        Zero

        No protection tube

        One

        No fixed device

        Two

        Fixed thread

        Three

        Movable flange

        Four

        Fixed flange

        Five

        90 degree angle flange

        Six

        Fixed thread taper

        Code

        Installation of armor type

        One

        No fixed device

        Two

        The fixed clip sleeve thread

        Three

        Flecible thread

        Four

        The fixed clip sleeve flange

        Five

        The movable ferrule flange


        Code

        Connection box

        Zero

        Simple type

        One

        Ordinary type

        Two

        Splash proof (waterproof type substitution)

        Three

        Waterproof type

        Four

        Explosion proof type

        Six

        Socket type

        Seven

        With the connecting wire type


        Code

        Armoured armoured body diameter

        Three

        Phi 3mm

        Four

        Phi 4mm

        Five

        Phi 5mm

        Six

        Phi 6mm

        Eight

        Phi 8mm

        Code

        The diameter of the outer protection tube assembly (full armor)

        Zero

        Phi 16mm

        One

        Phi 12mm

        Heat resistance A By ordering protocol.

        Note: the connector form, convenient installation, suitable for measuring -200-450 Liquid, gas and solid surface temperature range.

        The design and selection of notes:
        1, model;
        2, division no.;
        3, precision grade;
        4, fixed form;
        5, the length or depth of insertion.
        Customer service service commitment:
        1, my company sold Zhongwei Thermal resistance series The product within twelve months of quality problems, responsible for free maintenance.
        2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
        3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
        4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
        5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


        Browse:
        Return To The Top

        分亯到:

        jsGGc

        1. <dir id="mSLL8A"><q id="mSLL8A"></q></dir>