        PT100 thermal resistance

        26PT100熱電(dian)阻01.jpg
        • 26PT100熱(re)電(dian)阻01.jpg
        WZP series PT100 thermal resistance As the temperature measurement sensor, usually with temperature …

        Description:

        Productoverview:

        WZP series PT100 thermal resistance As the temperature measurement sensor, usually with temperature transmitter, controller and display instrument and other facilities, consisting of the process control system for direct measurement or control of the production process in a variety of -200 -500 DEG C range of liquid, steam and gas solids and surface temperature. Thermal resistance is the use of the material when the temperature changes with its own resistance characteristics change to measure the temperature. When the measured temperature gradient exists in the medium, the measured temperature is the average temperature of the temperature sensing element to the range of medium. Although the shape differences between the various thermal resistance is large, but their basic structure but broadly similar, generally have a temperature sensing element, insulating sleeve, protective tube, the main part and the junction box etc..

        Two, work principle:

        WZP series of <strong> PT100 thermal resistance</strong> is the use of the material when the temperature changes, the resistance also changes with the characteristics to measure the temperature. When the resistance changes, the instrument will display relevant resistance temperature.

        Three, technical parameters:

        Product executive standard

        IEC584

        IEC1515

        GB/T16839-1997

        JB/T5582-91

        Insulation resistance at room temperature

        Heat resistance at ambient temperature is 15 to 35 DEG C, relative humidity is less than 80%, the test voltage is 10 - 100V (DC) >100M. The insulation resistance between electrode and outer tube.

        Four, measurement of temperature and tolerance:

        ModelGraduationMeasuring rangePrecision gradeAllowable error
        WZPPt100-200-+500A(0.15+0.002) LTL.
        B(0.30+0.005) LTL.
        WZCCu50 Cu100-50-+100-(0.30+0.005) LTL.

        Note: t is the sense of temperature measured temperature component values (c)
        Five, Selection table:

        Code

        PT100 thermal resistance (Jiangsu Zhongwei)

        W

        Temperature instrument


        Code


        Z

        Heat resistance


        Code

        The temperature measuring element

        P

        Pt100 Pt1000 (the order required)

        C

        Cu50


        Code


        K

        Armoured type (assembled the symbol)


        Code



        Single

        Two

        Double branch


        Code

        Installation assembly (armoured)

        Zero

        No protection tube

        One

        No fixed device

        Two

        Fixed thread

        Three

        Movable flange

        Four

        Fixed flange

        Five

        90 degree angle flange

        Six

        Fixed thread taper

        Code

        Installation of armor type

        One

        No fixed device

        Two

        The fixed clip sleeve thread

        Three

        Flecible thread

        Four

        The fixed clip sleeve flange

        Five

        The movable ferrule flange


        Code

        Connection box

        Zero

        Simple type

        One

        Ordinary type

        Two

        Splash proof (waterproof type substitution)

        Three

        Waterproof type

        Four

        Explosion proof type

        Six

        Socket type

        Seven

        With the connecting wire type


        Code

        Armoured armoured body diameter

        Three

        Phi 3mm

        Four

        Phi 4mm

        Five

        Phi 5mm

        Six

        Phi 6mm

        Eight

        Phi 8mm

        Code

        The diameter of the outer protection tube assembly (full armor)

        Zero

        Phi 16mm

        One

        Phi 12mm

        Six, Design selection and ordering information:
        1, model;
        2, division no.;
        3, precision grade;
        4, fixed form;
        5, the length or depth of insertion . 
        Customer service service commitment:
        1, my company sold Zhongwei Thermal resistance series The product within twelve months of quality problems, responsible for free maintenance.
        2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
        3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
        4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
        5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, 48 hours outside users arrive at the scene.