1. <dir id="mSLL8A"><q id="mSLL8A"></q></dir>

        Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
        0517-86918678
        Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
        Tel:0517-86918678
        Fax:0517-86918679
        Email:zhongweick@https://zhanhaojiuye.com
        Post Encoding:211600

        Intelligent electrical contact liquid level display controller

        5智能(neng)電接點液(ye)位(wei)顯示(shi)控製(zhi)儀XMYA-6000.png
        • 5智(zhi)能電(dian)接點(dian)液位(wei)顯(xian)示(shi)控製儀XMYA-6000.png
        The intelligent electrical contact liquid level display controller receives the liquid level switch …

        Description:

        Products overview:

        ZW - XMYA seriesIntelligent electric contact liquid level display control deviceAdopted the self-developed research and development, the committee drag integrated circuit manufacturers custom production of application-specific integrated circuit.Acceptable level switch signals, it can be set respectively each level value of the liquid level switch, the LED digital form and light bar indicates the current level, and it can communicate with computer.Apply to, and a variety of electric contact liquid level gauge and float liquid level gauge, for boiler drum water level and other liquid level measurement display.

        Second, the main functions:

        1, can receive input 32 points, 32 can be arbitrary configuration below.

        2, with digital and beam in the two groups, according to the use of intuitive and convenient.

        3, with 1-3 road analog output.

        4, four alarm output can be set, alarm method can reach more than ten kinds of, and to monitor alarm parameters.

        More than 5, can provide host, single host, the host mode of RS485 asynchronous serial communication mode.Communication data verified in accordance with CRC - 16 U.S. data communication standard, high reliability circulation, barcode efficacy.

        Note: additional optional a variety of functions, its serial number add note when you order it, 4, 5, 6 can only choose a kind of additive and its function.

        Four, according to instructions:

        Article 1, single + single simulation

        Single digital tube display of dry contact input signal measurement.

        Single article simulation display as a percentage of dry contact input signal measurement

        The cursor displays the SP1 and SP2 alarm parameters of the relative range of percentage.

        2, light

        A lamp or J1 lamp, SP1 is alarm indicator lights

        E light or J2 light, is SP2 alarm indicator lights

        Lamp or J3 lamp, B is SP3 alarm indicator lights

        C lights or J4 lights, is SP4 alarm indicator

        Five, the selection table:

        ZW-XMYA

        Twenty - twenty - twenty

        Said Ming

        Design sequence

        6


        In the intelligent electric contact liquid level display control device (wei measurement and control)

        Display mode

        1

        2


        Single + single beam

        Please indicate the special display mode (order)

        Input points

        1-32


        Can be arbitrarily set the input points (set in the menu B BC)

        Control the output

        0

        1

        2

        3

        4


        No alarm output

        Alarm output all the way

        The second alarm output

        Three alarm output

        Four alarm output

        Overall dimensions

        H

        V


        Horizontal opening 152 x 160 x 80, 76

        Vertical opening 76 x 80 x 160, 152

        Analog output

        A

        B

        C

        D

        E

        F


        There is no analog output

        Analog 0 ~ 10 mA

        Analog output 4 ~ 20 mA

        Analog 0 ~ 5 V

        Analog output 1 ~ 5 V

        Special signal analog output

        Timing function

        S


        Default is no timing function

        With the function of timing

        Communication interface

        T


        The default is not to bring a communication interface

        With RS485 and RS232 communication interface

        Power supply

        K

        W

        Default is 220 v AC

        Switching power supply of 85 ~ 260 vac

        Switching power supply 18 to 36 VDC or 18 ~ 36 vdac

        After-sales service commitment:

        1, our company sold by wei measurement and control products quality problems within twelve months, responsible for free maintenance.

        2, the warranty period, any quality problems such as the products of our company, my company is responsible for free repair or replacement.

        3, the warranty period, such as user improper use, damaged products, my company is responsible for the maintenance, charge damage parts cost.