1. <dir id="mSLL8A"><q id="mSLL8A"></q></dir>

        Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
        0517-86918678
        Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
        Tel:0517-86918678
        Fax:0517-86918679
        Email:zhongweick@https://zhanhaojiuye.com
        Post Encoding:211600

        High temperature resistant fluorine plastic wire and cable installation

        耐高(gao)溫(wen)氟(fu)塑(su)料(liao)安裝(zhuang)線(xian)及電纜(lan).jpg
        • 耐(nai)高溫氟(fu)塑(su)料(liao)安(an)裝線及電纜(lan).jpg
        High-temperature fluorine plastic installation of wire and cable is suitable for the condition of hi…

        Description:

        One, the cable's brief introduction:
        High temperature resistant fluorine plastic wire and cable installationIs suitable for the condition of high temperature and low temperature conditions or special environment (such as acid, alkali, oil, chemical reagent, etc.) for electrical equipment or instrument equipment connection, and the conditions of the cables.
        Second, high temperature resistant fluorine plastic installation of wire and cable type and name:
        Fep insulation installed line (hereinafter referred to as F46 installation line).
        AF46 - fep insulated line installation.
        AF46P - fep insulation shielding line installation.
        AF46F46P - fep insulation shielding sheathed wire (cable) installation.
        Can install fusibility teflon insulation line (hereinafter referred to as installation line).
        AF4 - teflon insulation line installation.
        AF4P - teflon insulation shielding line installation.
        3, high temperature resistant fluorine plastic wire and cable installation using features:
        The working voltage of electric wires for ac rated voltage 500 v, dc voltage 1000 v, according to different conductor wire core material, its long-term use temperature
        No more than: tin conductor is 150 ℃, silver plated copper conductor is 200 ℃, nickel plated copper conductor is 260 ℃.
        Insulation resistance: (20 ℃) not less than 1000000 m Ω m..
        Four, size reference data (specification)

        sequence
        No.
        Wire core standard
        According to section
        (mm2)
        Wire core nominalThe biggest diameter (mm)The weight kg/kmAt 20 ℃
        Direct current (dc)
        The resistance is not big
        In Ω/KM
        The biggest
        cabling
        some
        The number/diameter
        (mm)
        Outer diameter
        (mm)
        AF46AF46PAF46 
        AF46P
        AF4AF4PAF46AF46PAF4AF4P
        10.207/0.200.601.351.852.61.41.954.238.654.9110.219024
        20.3519/0.150.751.62.12.91.62.26.5712.576.7912.095820
        30.5019/0.180.901.752.253.11.82.48.0514.219.0216.6841.316
        40.7519/0.231.152.02.63.52.02.611.7420.713.4821.5424.616
        51.0019/0.261.302.22.753.62.32.914.323.2116.2225.9619.312
        61.5019/0.321.602.63.34.12.73.321.532.523.3333.5312.712
        72.0019/0.371.852.93.64.43.03.627.839.1529.9340.4310.28
        82.5049/0.262.343.54.14.93.54.236.3450.0238.350.707.48
        93.0049/0.282.523.74.35.33.84.541.5455.544.657.276.454
        104.0049/0.322.884.24.95.94.24.957.275.257.275.205.04
        115.0049/0.363.244.65.36.34.65.369.392.969.392.94.12
        126.0049/0.393.514.65.96.64.95.680.15104.180.15104.03.32

        Five, the length of delivery:
        Cable and wire into a loop length of 100 m, allowing less than 2 m of short-term period of delivery the quantity does not exceed 10% of the deliveries.When placing order, indicate the internal insulation. The color requirement.