        Low smoke zero halogen flame retardant control cable

        低煙(yan)無滷阻(zu)燃控製電纜(lan).jpg
        • 低(di)煙無滷(lu)阻(zu)燃控(kong)製電纜(lan).jpg
        Low smoke zero halogen flame retardant control cable is suitable for ac 50 to 60 hz, rated voltage 7…

        Description:

        An overview, cables:
        Low smoke zero halogen flame retardant control cable is suitable for ac 50 to 60 hz, rated voltage 750 v and below, low smoke, halogen-free, non-toxic, non-corrosive, non-pollution cable) flame retardant requirements used as control monitoring circuit, etc.
        Second, the production of standard:
        Low smoke zero halogen flame retardant control cable to the enterprise standard and reference to GB9330-88 this product is suitable for use in ac 50 to 60 hz, rated voltage 750 v and below, low smoke, halogen-free, non-toxic, non-corrosive, non-pollution cable) flame retardant requirements used as control monitoring circuit, etc.
        Three control cables, low smoke zero halogen flame retardant technology performance:
        The product reference articles IEC227, IEC1034, IEC332 international standard design
        Four control cables, low smoke zero halogen flame retardant performance requirements:
        1, into A bundle of burning A or B, (coking section height) : 2.5 m or less.
        The distance of 2, secondary (without burning) : 50 mm or higher;
        3, smoke degree (minimum light transmittance) 60% or higher;
        4, HCL content acuities were 0.5 mg/g.
        Five, the model name:

        model

        The name of the cable

        KVV

        Copper low smoke zero halogen polyolefin insulated and sheathed flame-retardant control cable

        KVVP

        Copper low smoke zero halogen polyolefin insulated and sheathed woven block flame-retardant control cable

        KVVP2

        Copper low smoke zero halogen polyolefin insulated and sheathed copper tape screened flame-retardant control cable

        KVV22

        Copper low smoke zero halogen polyolefin insulation and sheath steel tape armoured flame-retardant control cable

        KVVR

        Copper low smoke zero halogen polyolefin insulated and sheathed flame-retardant control cable

        KVVRP

        Copper low smoke zero halogen polyolefin insulated and sheathed textile block flame-retardant control cable

        KVVP2-22

        Copper low smoke zero halogen polyolefin insulated and sheathed copper belt BingBiGang belt sheathed flame-retardant control cable

        KYJY

        Copper core with cross-linked polyethylene insulation polyolefin sheath low smoke zero halogen flame retardant control cable

        KYJYP

        Cross-linked polyethylene insulating tape armored low smoke zero halogen (B or C) A kind of flame retardant power cable

        KYJYP2

        Communication polyethylene insulated fine steel wire armoured low smoke zero halogen (B or C) A kind of flame retardant power cable

        KYJYP3

        Copper core with cross-linked polyethylene insulation polyolefin sheath aluminum-plastic composite belt shielding low smoke zero halogen flame retardant control cable

        KYJY23

        Copper core with cross-linked polyethylene insulation polyolefin sheath steel tape armoured low smoke zero halogen flame retardant control cable

        KYJYP2/23

        Copper core with cross-linked polyethylene insulation polyolefin sheath copper tape BingBiGang tape armored low smoke zero halogen flame retardant control cable

        KYJYP3/23

        Copper core with cross-linked polyethylene insulation polyolefin sheath with lu: su composite BingBiGang armoring low smoke zero halogen flame retardant control cable

        "WDZ" : it means low smoke zero halogen flame retardant
        Six, cable specifications:

        model

        Conductor nominal section (was)

        0.5

        0.75

        1.0

        1.5

        2.5

        4

        6

        10

        some

        KVV
        KVVP

        -

        2 ~ 61

        2 ~ 14

        2 ~ 10

        KVV2

        -

        4-61

        4 ~ 14

        4 ~ 10

        KVV22 
        KVVP2-22

        -

        7 ~ 61

        4-61

        4 ~ 14

        4 ~ 10

        KVVR

        -

        4-61

        -

        -

        KVVRP

        -

        4-61

        4 ~ 48

        -

        -

        Note: recommend some series for: 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 44, 48 and 52 and 61 core.
        Seven, delivery requirements:
        1, into a circle of 100 m, a dish should be greater than 100 m;
        2, according to the supply and demand both sides agreement to allow any length of delivery, the length of the measurement error of plus or minus 0.5%.